Keep any threading compound off of the first two pipe threads to avoid having any small pieces of compound break loose and clog a burner valve or orifice. do not put sealant on any male end of flare fittings

Keep last two threads clean

for built-in ommen

pipe used be kept as short as possible. (see indeX: “ g as

Connections” for typical permanent hook up.)

for freestanding units using natural gas, Lynx strongly recommends using a quick

lP gAs

g rills set up for lP gas come equipped with an lP hose/ regulator assembly for con nection to a standard 20 lb. lP cylinder. (Type 1). All fittings necessary to attach the assembly to the grill are

i

Permanently plumbed lP con- nections, such as those in line with a bulk cylinder, require

a4/11 regulator. (lynx P/n 30781)

i f you are using a 4/11

m axitrol regulator, ensure that it is set for the correct fuel by adding or removing the cap asket as shown below.

gas line to the grill.

warning

Do not change the regulator/hose assembly or use any other assembly than the one supplied with your Lynx grill.

Do not attempt to use a 5LP-A equipped regulator/ hose assembly with a standard 510 POL cylinder/ valve assembly.

Do not store a spare LP-gas cylinder under or near this appliance

Never fill the cylinder beyond 80 percent full

If the information above is not followed exactly, a fire causing death or serious injury may occur.

lP Cylinder

requirements

The lP cylinder must be con- structed and marked in accor dance with the specifications for lP gas cylinders of the u s department of Transportation

(doT) and designed for use with a Type 1 system only.

cylinders must be secured sing the provided cylinder etention system to avoid ccidental movement.

cylinder for a refill, exchange only for a Type 1 20lb cylinder with an over-fill protection device.

n ever use a cylinder with a damaged valve.

A dented or rusty lP cylinder may be hazardous and should be avoided. If in doubt, have it checked by your lP supplier.

Always check for leaks after every lP cylinder change.

(see indeX: “ leak Test” for further details.)

Always shut off the lP-gas supply at the cylinder when the grill is not in use.

cylinders must be stored outdoors in a well-venti- lated area out of the reach of children. If your grill is stored indoors, the lP cylinder must be stored outside.

connection