P 34/ 37
Wiring diagram
Fig. D-2D
Wiring in Motor Housing and Handle for 220 - 240V area where Radio Interference suppression is not required.
Field lead wires have to be tightened in the Motor housing so as not to touch Armature.
Insulated terminal
Do not put Lead wires on these ribs.
Controller
Field Lead wire (white) Field Lead wire (purple)
Do not route Field lead wires (white and purple) between Armature and Baffle plate.
Field Lead wires * (orange)
*(black)
*(yellow)
rib
Case of Power | ribs for Laser |
supply circuit | switch unit |
Pass Lead wires from Motor housing through the notch of Handle.
Pass Lead wires through ribs as illustrated.
Do not put their Lead wires on the ribs. Switch for protection of brake coil
Connection of Receptacles
Receptacles have to be connected so that their wire connecting portions face the bottom of Handle.
Receptacles
Bottom of Handle | Wire connecting portion |