P 33/ 37

Wiring diagram

Fig. D-2A

Wiring in Motor Housing and Handle for Argentina and

220 - 240V area where Radio interference suppression is required.

Field lead wires have to be tightened in the Motor housing so as not to touch Armature.

Terminal block

Controller

Field lead wire (white)

 

Field lead wire (purple)

Field lead wires

 

* (orange)

Do not route Field lead wires

* (black)

(white and purple) between

* (yellow)

Armature and Baffle plate.

 

Pass the Lead wires from Motor housing through this notch of Handle.

rib

case of Power

rib for Laser

supply circuit

switch unit

Pass Lead wires through ribs as

 

 

 

 

illustrated.

 

Switch for protection

Do not put Lead wires on ribs.

 

 

of brake coil

 

 

 

 

 

 

 

 

 

 

 

 

Connection of Receptacles

 

 

 

 

 

 

 

 

 

The Receptacles have to be connected so that their wire connecting portions face the bottom of Handle.

Receptacles

Bottom of Handle

Wire connecting portion

Page 33
Image 33
Makita LS1016L dimensions Fig. D-2A