P 36/ 37

Wiring diagram

Fig. D-2B

Wiring in Motor housing and Handle for UK 110V

Field lead wires have to be tightened in the Motor housing so as not to touch Armature.

Terminal

 

block

Do not put Lead wires on ribs.

Controller

Field lead wires

*(orange)

*(black)

*(yellow)

rib

case of Power

ribs for Laser

supply circuit

switch unit

Pass Lead wires from Motor housing through the notch of Handle.

Pass the Lead wires through the Rib for Laser switch unit. Do not put the Lead wires on the Ribs.

Wiring on Line filter

Lead wire (black) for connecting

Main switch and Terminal block

Wind Lead wires to Line filter one time as illustrated right.

Lead wre (red) for connecting

Line filter

Controller and Terminal block

 

Page 36
Image 36
Makita LS1016L dimensions Wiring in Motor housing and Handle for UK