CONNECTING SUPPLY LINES

Section 2

Installation

 

 

2.Connect the circulating water by connecting one line to the circulating pump outlet line (3/8” barb) and clamp in place. Connect the other line to the bulkhead return fitting located by the agitator motor (3/8” barb) and clamp in place.

3.Connect the conduit lines. Two (2) carbonated water lines and two (2) product output lines (#1 regular rootbeer & #2 diet rootbeer)

CONNECTING SUPPLY LINES

Braided CO2

Gas Line

Black Water

Supply Line

Color Coded

Syrup Lines

Connect water supply inside unit.

Water Supply & Regulator

Pre-installation of towers is required and the appropriate syrup supply must be connected to the corresponding tower.

Proceed with the Following Tests

Ensure that overflow tube is firmly seated, not leaking.

Check conduit for proper support and insulation.

Cycle carbonator “A” momentarily.

Cycle circulating Motor “A” momentarily.

Cycle compressor momentarily.

Ensure that agitator motor is running.

Ensure that ice bank control probe is securely attached to evaporator coil.

Connect CO2 supply inside unit.

CO2 Supply & Gauge

Connecting conduit at the refrigeration unit

1.Connect the product lines either from the bag-in-box or tank (#1 regular rootbeer & #2 diet rootbeer). See the plumbing diagrams for the tower setup that pertains to your installation.

2.Insert the Multipar conduit into the outlet opening on the left hand side of unit. Conduit insulation must extend inside of opening in unit for proper operation of equipment.

Insulated

Beverage

NOTE: Multipar conduit is color coded for easy identification of lines. When making connections always attach lines requiring the longest connection from the insulation first. The remaining lines can be trimmed as required to make the routing neat and secure.

3.Locate the two blue carbonated water lines of the Multipar conduit. Attach one of the blue lines to the tee fitting located on top of the carbonator tank. Attach the other blue line to John Guest elbow fitting on the stainless coil labeled “8”.

4.Locate the black plain water line of the Multipar conduit. Attach this line to the elbow fitting on the stainless coil labeled “W”.

5.The remaining lines of the Multipar conduit are syrup supply lines and must be attached to the appropriate elbow fittings on stainless steel syrup coils. Note the numbered lines attached to the opposite end of each syrup coil when making connections.

Part Number 020001552 5/11

2-13

Page 23
Image 23