Before Calling for Service

Section 5

Before Calling for Service

 

 

Section 5

Before Calling for Service

Checklist

If a problem arises during operation of your post mix soda refrigeration unit, follow the checklist below before calling service. Routine adjustments and maintenance procedures are not covered by the warranty.

!Warning

Only trained and certified electrical and plumbing technicians must service this unit. All wiring and plumbing must conform to national and local codes.

Problem

Possible Cause

To Correct

Water only dispensing:

Regulator(s) out of adjustment

Check/adjust regulator(s).

No pressure

 

 

Out of CO2

Install fresh tank.

 

Defective regulator(s)

Check/repair/replace regulator(s).

 

CO2 line pinched, kinked, or obstructed

Check/repair/replace CO2 line.

Syrup and CO2 only dispensing:

No power

Check poser supply. Plug in carbonator

Carbonator

 

or reset breaker.

 

Water supply

Make sure water is turned ON.

 

 

Replace water filter.

 

 

Check/clean/replace pump strainer.

 

 

Check/clean/repair water check valve.

 

 

Check for frozen water line.

 

 

Internal Carbonator unit only.

 

Defective carbonator

Check/repair/replace carbonator pump,

 

 

motor, electrode or liquid level control.

Syrup and plain water only dispensing:

Out of CO2

Install fresh tank.

No pressure

HP regulator out of adjustment

Adjust HP regulator to the proper setting.

 

Defective HP regulator

Check/repair/replace HP regulator.

 

CO2 line pinched, kinked, or obstructed

Check/repair/replace CO2 line.

One valve will not dispense anything:

Broken wire or loose connection

Replace/repair wire or connector.

Is there power to the valve?

 

 

Bad microswitch

Replace microswitch.

Beverage dispensed is too sweet:

Flow control out of adjustment

Adjust the flow control.

Is the ratio (brix) of the drink correct?

Insufficient soda flow due to low

Adjust CO2 pressure or change the tank.

 

carbonator pressure

 

 

Low CO2 pressure due to leaks

Repair CO2 leaks.

 

Obstruction in the water or soda line

Clean out the lines.

Beverage is not sweet enough:

Flow control out of adjustment

Adjust the flow control.

Is the ratio (brix) of the drink correct?

Soda flow too high

Reset CO2 pressure or replace regulator

 

 

if necessary.

 

Obstruction in syrup line

Clean out the syrup line.

Drinks are foaming:

Over carbonation

Check CO2 supply. Reset pressure or

Are system pressures correct?

 

replace regulator is necessary.

 

Dirty lines/valves

Clean sanitize entire system.