Marathon RJ-88SC, RJ-250VL Electrical & Hydraulic Installation, Remote Power Pack Installation

Models: RJ-250SC RJ-100SC RJ-250VL RJ-88SC

1 39
Download 39 pages 41.58 Kb
Page 32
Image 32

3 INSTALLATION

ELECTRICAL & HYDRAULIC INSTALLATION

3-3

 

 

The motor control panel contains high voltage components. Only authorized service personnel should be allowed inside. See Lock-Out & Tag-Out instruc- tions in the maintenance section.

A lockable fused disconnect switch (customer furnished) must be installed and be within sight of the compactor motor control panel location, not to exceed 50'0" from the com- pactor. This fused disconnect switch should be sized in accordance with the compactor (see Fuse and Circuit Breaker Chart).

CAUTION: All equipment should be grounded per National Electric Code.

REMOTE POWER PACK INSTALLATION

1.The remote power pack should be installed and anchored as required by the cus- tomer. If the operator station is mounted in the face of the motor control panel, be certain these controls are located as to be in a convenient, but not hazardous, loca- tion to the customer.

CAUTION: Operator Station must be located so that the Mushroom (Emergency) Stop Button is readily accessible to the operator and within three (3) feet of the charging chamber access door. If installation requires the operator station to be located in a more remote area, a second Emergency Stop Button should be added and installed in the manner described above.

2.For a through-the-wall power pack installation, see the diagram THROUGH-THE- WALL POWER UNIT INSTALLATION at the end of this manual. Special care should be taken to protect the hoses from abrasive objects.

3.Connect the hydraulic hoses to the power pack, exercising care to follow the port decals (A or B) on the packer and the power pack. In the event the decals have been obliterated, the hose leading from the rear of the cylinder should be installed in the side port of the block to which solenoid valve is bolted (A Port). The hose leading from rod end of the cylinder should be connected to the end of the block to which the solenoid valve is bolted (B Port). Refer to Power Unit diagrams in the Maintenance section of this manual.

Page 32
Image 32
Marathon RJ-88SC, RJ-250VL, RJ-100SC, RJ-250SC Electrical & Hydraulic Installation, Remote Power Pack Installation