CUSTOMER RESPONSIBILITIES
Thank You for purchasing a Maytag water heater. Properly installed and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact Maytag Customer Service (1-
Abbreviations Found In This Instruction Manual:
•EPACT - Energy Policy A ct
•UL - Underwriters Laboratories Inc.
•CAN - Canada
•CSA - Canadian Standards Association
•NFPA - National Fire Protection Association
•ANSI - American National Standards Institute
•ASME - American Society of Mechanical Engineers
•GAMA - Gas Appliance Manufacturer’s Association
This
•Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the
ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
•The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the Natural Gas and Propane Installation Code
•If after reading this manual you have any questions or do not understand any portion of the instructions, call Maytag
Customer Service at
•Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires, see Figures 9 through 14.
Examine the location to ensure the water heater complies with the Locating and Installing the New Heater section in this manual.
PRODUCT SPECIFICATIONS
|
| TANK |
|
| RECOVERY | MINIMUM |
| DIMENSIONS | |
|
| CAPACITY | TYPE |
| RATE GALS. | VENT PIPE | DIAMETER | IN INCHES (mm) | |
|
| IN GALS | OF | BTU | PER HOUR | INCHES | INCHES | HEIGHT TOP OF | |
MODEL NUMBER | (LTRS) | GAS | RATE | @ 90°F RISE | (mm) | (mm) | DRAFT HOOD | ||
HXN4975S | 75 (284) | NATURAL | 75,100 | 81.0 | 4" (102) | 26 3/8" (670) | 61 1/8" (1,553) | ||
HXP4975S | 75 (284) | PROPANE | 75,100 | 81.0 | 4" (102) | 26 3/8" (670) | 61 1/8" (1,553) | ||
|
|
|
|
|
|
|
|
|
|
5