Power Supply Cord
Fire Hazard
Use anew UL listed 30 amp power supply cord.
Use aUL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to de so can result in death, fire, or
electrical shock.
Direct Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
A B C D

......

E
F
A. 7_'rminal block cov_'r
B. [-xternal ground conductor
sL r_'vV
C. O_nt_'l; silver-color_'d t_'rminal
block screw
D. Hold-down scr_'wlocation
E. Neutral ground wire
F. Hole below tem'linal block
opening
Style 1: Power supply cord strain relief
Remove the screws from a ¾" (1.9 cm) U[. listed strain relief (UL marking on strain
relief). Put the tabs of the two clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is pointing down, and hold in
place. Tighten strain relief screws just enough to hold the two clamp sections together.
A. Strain relief tab pointing LIp
B. Hole below t_'rminal block opening
C. Clamp section
D. Strain relief tab pointing down
3. Install strain relief.
8