Power Supply Cord

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to de so can result in death, fire, or electrical shock.

1. Disconnect power.

2.Remove the hold-down screw and terminal block cover.

AB C D

A. 7_'rminal block cov_'r

B. [-xternal ground conductor sL r_'vV

C. O_nt_'l; silver-color_'d t_'rminal block screw

......D Hold-down scr_'wlocation

E Neutral ground wire

E

F Hole below tem'linal block opening

F

3.Install strain relief.

Direct Wire

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

Style 1: Power supply cord strain relief

Remove the screws from a ¾" (1.9 cm) U[. listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.

A. Strain relief tab pointing LIp

B. Hole below t_'rminal block opening

C. Clamp section

D. Strain relief tab pointing down

8

Page 8
Image 8
Maytag MED5591TQ1, W10088776A, MED5591TQ0 manual Ab C D