ELECTRONIC CONTROL SETUP

IMPORTANT

Electrostatic Discharge (ESD)

Sensitive Electronics

ESD is presenteverywhere.ESD may damageor weakenthe electronic controlassembly.The new controlassemblymay appear to work well after repair is finished,but failuremay occur at a later date due to ESD stress.

Use an anti-static wrist strap. Connectwrist strap to green earth connection point or unpainted metal in the appliance.

-OR-

Touch your finger repeatedly to a green earth connection point or unpainted metal in the appliance.

Before removing the part from its package,touch the anti-static bag to a green earth connectionpoint or unpainted metal in the appliance.

Avoidtouchingelectronic parts or terminal contacts;handle electronic controlassembly by edges only.

When repackaging failed electronic controlassemblyin anti-static bag, observe above instructions.

GENERAL USER INFORMATION

“out of order” showingin display

This condition indicates the dryer is inoperative.Diagnosticor failure code will follow the scrolling message.

0 Minutes’ showing in display

This conditionindicates the dryer cannot be operated. Coins dropped or debit inputs during this condition will be storedin escrow but cannot be used until normal operationis restored by opening and closing the door. If a door switch fails,it must be replaced beforenormaloperation can be restored.

Cold Start (initial first use)

Dryer is programmed at the factoryas follows:

45 minutes dry time for PN models;5 minutesper coin for PD models.

1.50 dry price (fixed cycle with top off - PD Models).

0.00 dry price (fixed cycle - PN Models).

WarmStart (after power failure)

A few secondsafter power is restored,if a cycle was in progress at the time of the power failure, ‘RESELECT CYCLE’will flash in the display. This is to indicate the need for a fabricsetting button to be pressed to restartdryer.

Pricing

After the door is openedand closedfollowingthe completionof

acycle,the displayindicatesthe cycleprice(unlessset for free operation). As coinsor debitinputsarrive,the displaywill change to lead the user through the initiationof a cycle.

Thereare four (4) typesof pricing:

Fixed ‘Vend’ Pricing

A dryer set up for ‘Fixed Cycle’ operation can only accept additional time accumulated by increments equal to the length of a complete dry cycle. A maximum of 99 minutes may be purchased; no additional credit is given when 99 minutes is in the display.

Accumulator Pricing

If the price is set to one coin 1, then accumulator mode is in effect. Cycle time can be purchased one coin at a time (PD models) up to the maximum time of 99 minutes.

Fixed Cycle With Top Off Pricing

A dryer set to offer ‘Top Off’ capability will allow time to be added to an existing dry cycle in increments equal to the number of minutes of dry time per coin (coin 1), up to 99 minutes, regardless of the cost required to start the dryer. No credit is given for coins or debit inputs entered when the control is displaying 99 minutes.

PN Models Set Up As PR: In Enhanced Debit Mode, the top off price can be set independently (see VALUE OF COIN 2), and the top off time is calculated according to the following equation:

top off price

=

top off time

full cycle price

full cycle length

Hundredth increment offset is not applied to top off purchases.

PN Models

The factory has preset the cycle price to zero. When this happens, ‘SELECT CYCLE’ will appear rather than a cycle price. Any cycle started as a free cycle will automatically terminate when the door is opened.

Debit Card Ready

This dryer has a control that is debit card ready,but the dryer is not.

13

Page 13
Image 13