MAINTENANCE INSTRUCTIONS

Maintenance instructions:

Clean lint screen after each cycle.

Removing accumulated lint (disconnect dryer from electricity and gas supplies before starting this task):

From inside the dryer cabinet:

Lint should be removed every 2 years or more often, depending on dryer usage. Cleaning should be done by a qualified person.

From the exhaust vent:

Lint should be removed every 2 years, or more often, depending on dryer usage.

If dryer does not operate, check the following:

Electric supply is connected.

Circuit breaker is not tripped or fuse is not blown.

Door is closed. Listen closely to hear door switches activate.

Selected cycle button has been pressed firmly and display shows cycle time.

Check that gas supply shutoff valves are set in open position.

If you need assistance:

Contact your authorized Maytag Commercial Laundry distributor or visit: www.MaytagCommercialLaundry.com.When you call, you will need the dryer model number and serial number.

Both numbers can be found on the serial-rating plate located on your appliance.

TECHNICAL SPECIFICATIONS - GAS DRYER

220-240V~50Hz 1ph 3A max. IP24 Clothes capacity: 9.0 kg max. Sound pressure level, Lpa: 58 dBA

(uncertainty, Kpa: +/–10 dBA) Total mass: 68 kg max.

Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW

European Country:

CH, CZ, CY, ES, GB, GR, HR,

 

CY, CZ, DK, EE, FI, GR, HU, IT,

 

IE, IT, PT, SI, SK, TR

 

NO, RO, SE, SK, TR

European Gas Category:

II2H3+

 

II2H3B/P

Gas Flow Rate:

0.562703 m3/hr

 

0.562703 m3/hr

Supply Pressure (G20):

20 mbar

 

20 mbar

 

 

 

 

Factory Adjusted Pressure:

7.4 mbar

 

7.4 mbar

 

 

 

With LP Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4

kW

 

 

 

 

European Country:

CH, CZ, CY, ES, GB, GR, HR,

 

CY, CZ, DK, EE, FI, GR, HU, IT,

 

IE, IT, PT, SI, SK, TR

 

NO, RO, SE, SK, TR

 

 

 

 

European Gas Category:

II2H3+

 

II2H3B/P

Butane Supply Pressure (G30):

28-30 mbar

 

30 mbar

Adjusted Pressure:

N/A

 

N/A

 

 

 

 

Propane Supply Pressure (G31):

37 mbar

 

30 mbar

Adjusted Pressure:

N/A

 

N/A

 

 

 

 

With France/Belgium NATURAL GAS conversion kit: Injector size: 1.65 mm

Heat input gross: 5.9 kW

European Country:

FR, BE

 

 

European Gas Category:

I2E+

Supply Pressure (G20):

20 mbar

 

 

Supply Pressure (G25):

25 mbar

Adjusted Pressure:

N/A

 

 

 

 

 

NOTE: Conversion kit: From Natural Gas to LP Gas: Whirlpool Part No. W10233219.

Conversion kit: From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10184947. Manufacturer: Whirlpool Corporation, 1300 Marion-Agosta Rd., Marion, OH 43302, USA.

EU representatives: Maytag UK Ltd., 2 St. Annes Blvd., Redhill, RH1 1AX, UK

& Bauknecht Hausgeräte GmbH, D-73614 Schorndorf, Germany

10