Recessed Area and Closet Installation Instructions

This dryer may be installed in a recessed area or closet. This dryer must not be installed behind a lockable door, a sliding door, or a door with a hinge on the opposite side to that of the dryer.

The installation spacingis in millimetersand is the minimumallowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.

If installed in a closet with a door, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.

The dryer must be exhausted outdoors.

No other fuel-burning appliance may be installed in the same closet as the dryer.

Minimum Installation Clearances

159 mm

(61/4")

ELECTRIC

 

 

715 mm

152 mm

 

(281/8")

 

89 mm

(57/8")

GAS

(31/2")

 

 

32 mm

 

358 mm

(11/4")

 

(14")

BACK VIEW

356 mm

(14") max

381 mm

(15")

Closet door

0 mm

0 mm

(0")

(0")

0 mm

(0")

25 mm (1")

736 mm

(29") 695 mm (271/4")

203 mm

(8")

Recessed front view

Closet side view

Additional clearances for wall, door, and floor moldings may be required or if external exhaust elbow is used.

921mm (361/4")

310cm2* (48 in.2 )

Front

view

155cm2* (24 in.2)

76 mm (3")

closet

door

76 mm (3")

*Opening is the minimum for a closet door. Louvered doors with equivalent air openings are acceptable.

25

 

mm

SIDE VIEW

 

(1")

 

Electrical Requirements – Gas Dryer

Product Dimensions 686 mm (27") dryer

686 mm

(27")

965mm

(38")

Important: Observe all governing codes and ordinances.

You will need an earthed electrical outlet located within 610 mm (2 feet) of either side of the dryer.

25

 

mm

FRONT VIEW

 

(1")

5

Page 5
Image 5
Maytag W10239207B Electrical Requirements Gas Dryer, Recessed Area and Closet Installation Instructions, Front View