Adding of liquid detergents and neutralizers

Priming the liquid dispensing systems

Before the machine is first used, and later if one or more containers has been allowed to empty, the dispensing system(s) for liquid media must be vented.

^Press the ON/OFF I-0button.

^Select operating level "B".

^Select from the following as required: Program DOS 1-FILL

Program DOS 3-FILL

(see under "Operation - B. Free program selection").

Optional:

Program DOS 2-FILL Program DOS 4-FILL

(if DOS 2 and/or DOS 4 pumps have been built in).

^Press the "Start" 6 button.

The DOS-FILL Service Program are allocated by default to program places 58-61, but they can be allocated to other program places.

Dispensing system maintenance

To ensure safe function the following maintenance should be carried out by a Miele Service Technician at specified intervals.

Every 12-18 months:

Inspect the hoses in the dispensing system(s). Replace if necessary.

External Dispensing systems

If external pumps are to be used for dispensing liquid detergent, please inform the Miele Technical Service Department. The notes in the Programming Manual under "Machine functions" must be observed.