Miele G 7855 manual Drainage, Plumbing

Models: G 7855

1 52
Download 52 pages 43.46 Kb
Page 50
Image 50
Drainage

Plumbing

Drainage

^The drainage system is fitted with a non-return valve which prevents dirty water from flowing back into the machine via the drain hose.

^The machine should preferably be connected to a separate drainage system on-site.

If separate drainage is not available contact your Miele application specialist for professional advice. The on-site drain connection point should be sited between 0.3 m and 1 m above the lower edge of the machine.

If it is lower than 0.3 m lay the hose in a curve at a height of at least 0.3 m. The drainage system must be able to take a minimum drainage flow of 16 l/min.

^The inlet hose is approx. 1.4 m long, is flexible and has an internal diameter of 22 mm. It must not be shortened.

Hose clips are supplied for securing it in position.

^A longer drain hose (up to 4 m long) is available to order from the Miele Spare Parts Dept.

^The drainage system must not exceed 4 metres.

See also the installation diagram supplied.

50