Water softener
Table of settings
|
|
|
|
°d | mmol/l | °f | Setting |
(German |
|
|
|
scale) |
|
|
|
|
|
|
|
1 | 0.2 | 2 | 1 |
2 | 0.4 | 4 | 2 |
3 | 0.5 | 5 | 3 |
4 | 0.7 | 7 | 4 |
5 | 0.9 | 9 | 5 |
6 | 1.1 | 11 | 6 |
7 | 1.3 | 13 | 7 |
8 | 1.4 | 14 | 8 |
9 | 1.6 | 16 | 9 |
10 | 1.8 | 18 | 10 |
11 | 2.0 | 20 | 11 |
12 | 2.2 | 22 | 12 |
13 | 2.3 | 23 | 13 |
14 | 2.5 | 25 | 14 |
15 | 2.7 | 27 | 15 |
16 | 2.9 | 29 | 16 |
17 | 3.1 | 31 | 17 |
18 | 3.2 | 32 | 18 |
19 | 3.4 | 34 | 19 *) |
20 | 3.6 | 36 | 20 |
21 | 3.8 | 38 | 21 |
22 | 4.0 | 40 | 22 |
23 | 4.1 | 41 | 23 |
24 | 4.3 | 43 | 24 |
25 | 4.5 | 45 | 25 |
26 | 4.7 | 47 | 26 |
27 | 4.9 | 49 | 27 |
28 | 5.0 | 50 | 28 |
29 | 5.2 | 52 | 29 |
30 | 5.4 | 54 | 30 |
31 | 5.6 | 56 | 31 |
32 | 5.8 | 58 | 32 |
33 | 5.9 | 59 | 33 |
34 | 6.1 | 61 | 34 |
35 | 6.3 | 63 | 35 |
36 | 6.5 | 65 | 36 **) |
37 | 6.7 | 67 | 37 |
38 | 6.8 | 68 | 38 |
39 | 7.0 | 70 | 39 |
40 | 7.2 | 72 | 40 |
41 | 7.4 | 74 | 41 |
42 | 7.6 | 76 | 42 |
43 | 7.7 | 77 | 43 |
44 | 7.9 | 79 | 44 |
45 | 8.1 | 81 | 45 |
|
|
|
|
|
|
|
|
|
|
|
|
°d / | mmol/l | °f | Setting |
mmol/l |
|
|
|
|
|
|
|
46 | 8.3 | 83 | 46 |
47 | 8.5 | 85 | 47 |
48 | 8.6 | 86 | 48 |
49 | 8.8 | 88 | 49 |
50 | 9.0 | 90 | 50 |
51 | 9.2 | 92 | 51 |
52 | 9.4 | 94 | 52 |
53 | 9.5 | 95 | 53 |
54 | 9.7 | 97 | 54 |
55 | 9.9 | 99 | 55 |
56 | 10.1 | 101 | 56 |
57 | 10.3 | 103 | 57 |
58 | 10.4 | 104 | 58 |
59 | 10.6 | 106 | 59 |
60 | 10.8 | 108 | 60 |
|
|
|
|
|
|
|
|
*) factory setting **)
Machines without a water softener are set to 0 at the factory. This setting of 0 must not be changed on these machines.