Programming special functions
For future servicing work, please document any alterations to the stan- dard factory settings.
Enter any alterations in the field Value set:_________.
General notes:
–Switch positions that have not been allocated a function are indicated in
the middle part of the display by a bar ( - ).
–The programming level is called up via the STOP position f.
–A number of global parameters and programme specific parameters can be altered.
Settings and alterations to global parameters (setting concentration levels for DOS 1) apply to all programmes in which the parameter is found.
Setting and altering programme specific parameters (Wash/Rinse temperatures and temperature holding times: Main wash and Final rinse) only applies to the programme in which this parameter is found.
1.Setting the dosage concentration and venting the dispensing system
^Turn the programme selector to STOP f.
^Switch off the machine.
^Press and hold ß and 6 at the same time, and whilst doing so, switch the machine on with the
The current programme status "P..." will appear in the display and the p / 6 indicator light will come on.
^Press 0 twice, E02 for programming level 2 will appear in the display.