Image 47
Electrical connection

Electrical connection

,All electrical work must be carried out by a suitably qualified and competent person in accordance with local and national safety regulations.

^Connection should be made via a suitable isolator, with an on-off switch which should be easily accessible for servicing work.

^For extra safety it is advisable to install a residual current device with a trip current of 30 mA (in accordance with DIN VDE 0664).

WARNING

THIS APPLIANCE MUST BE

EARTHED

^Equipotential bonding should be carried out.

Bonding connection

There is a screw connection point marked with the earth symbol (8) at the back of the machine, to which the earth lead must be connected.

^For technical data see data plate or wiring diagram supplied.

The machine must only be operated with the voltage, frequency and fusing shown on the data plate.

This machine can be converted in accordance with the conversion diagram and wiring diagram supplied.

The conversion diagram and data plate with test certification (VDE, DVGW etc.) is located on the rear of the machine, and on the plinth (behind the service panel).

The wiring diagram is secured to the inner side of the service panel.

To remove the service panel and plinth:

,Disconnect the machine from the mains electricity supply.

^Remove fixing screws a from the service panel.

^Take hold of the service panel at both sides and pull upwards.

^Unscrew plinth facing (screws b).

^Remove the plastic protective cap.