Miele G 890 manual Electrical connection, Permanent Connection Hard Wiring, Grounding Instructions

Models: G 890

1 72
Download 72 pages 19.44 Kb
Page 65
Image 65
Permanent Connection (Hard Wiring).

Electrical connection

Permanent Connection (Hard Wiring).

For hard wiring, the power cord must be disconnected from the terminal box located at the lower left front of the dish- washer, behind the toekick and service panel. Pass the permanent power sup- ply cable through the strain relief and secure it to the terminal box.

Connect:

L1 (Black) to L on terminal block

N(White) to N on terminal block GRND To ground connector

GROUNDING INSTRUCTIONS

This appliance must be connected to a grounded metal, permanent wiring system, or an equipment- grounding conductor must be run with the circuit conductors and con- nected to the equipment grounding terminal or lead on the appliance.

Use copper conductors only.

Warning.

Hardwiring the dishwasher should only be done if required by local electrical codes, and then in a manner consistent with those codes. Do not cut the plug off the power supply cord and connect it directly to the house wiring.

65

Page 65
Image 65
Miele G 890 manual Electrical connection, Permanent Connection Hard Wiring, Grounding Instructions