Miller Electric 625 manual Time/Amperage Control, Select TIME/AMP Adjustment

Models: 625

1 48
Download 48 pages 48.75 Kb
Page 26
Image 26

6-2. Time/Amperage Control

TIME (ms)

AMPERAGE

2

1

3

4

SELECT

TIME/AMP ADJUSTMENT

Ref. 232 187-A

1 Time/Amperage Select Button

Depress button to select Time/Amperage control.

2Time Meter

3Amperage Meter

4 Time/Amp Adjustment Control

Rotate knob clockwise to increase time/am- perage

STime - (5-1000 milliseconds)

SAmperage - (50-1000 amps)

Rotate knob counterclockwise to decrease time/amperage.

.The active display will be lit and adjust- able. The inactive display will turn off.

OM-216 244 Page 22

Page 26
Image 26
Miller Electric 625 manual Time/Amperage Control, Select TIME/AMP Adjustment