Installing

Install Peripheral Interface Cards

To install the Peripheral Interface cards:

CAUTION: To prevent static damage to electrical components, ensure that the system is grounded before you install the cards. Whenever you handle circuit cards, wear an anti-static strap.

1.Install the peripheral switch controller card in slot 16.

2.Set the E&M Trunk Card settings and the OPS Line Card Message Waiting Switches in the Peripheral Unit Specifications section.

3.Install the Peripheral Interface cards. Refer to Install a Circuit Card in "Install Upgrades and FRUs" for circuit card installation procedures.

Cable the Unit to the MDF

Cable the lines and trunks from the Peripheral Unit to the Main Distribution Frame (MDF) by using the Peripheral Interface Cabling Tables.

About Peripheral Interface Cabling

Peripheral equipment (e.g., stations, SUPERSET telephones, trunks) is connected to the relevant interface circuits of the system via a cross-connect field. Peripheral Interface cards, situated in slots 1 through 12, are connected to the cross-connect field by a maximum of eight 25-pair cables (customer-supplied) per Peripheral Unit. Cables terminate at the node on 50-pin plugs, J1 through J8, with the number of cables being dependent on the quantity and type of interface cards installed in the node.

Plugs J1 through J8 are hardwired to backplane connectors in slots 1 through 12 to form four slot groups, each comprising three adjacent cards and each associated with a pair of plugs. Two adjacent slot groups are shown in Backplane Connector Arrangements. The circuits of interface cards contained in a slot group are evenly distributed to the relevant pair of plugs, such that, half the circuits of each card in a group are connected to the odd-numbered plug and half to the even-numbered plug. Peripheral Wiring (Backplane) details the hardwire connections between one slot group and the associated plugs. The wiring sequence is identical for the remaining three slot groups.

Cable jacks (P1 through P8), are customer-supplied and should be labeled at time of installation. P1 through P8 are secured to J1 through J8 with hook and loop type fasteners. Equipment which is external to the system (i.e., system to cross-connect field cables and cross-connect field hardware) is not supplied by MITEL. Therefore, the type of equipment used and the layout of the cross-connect field cables is at the discretion of the installation company. Installation information for such equipment must be obtained from the equipment manufacturer.