![](/images/new-backgrounds/1049431/49431525x1.webp)
Troubleshooting
Troubleshoot the PRI Card
Faceplate LEDs
Three status LEDs and 4 circuit LEDs are mounted on the PRI card faceplate. Each of the card circuit LEDs shows the status of one PRI circuit.
| PRI Card Link Status | |
LED | State | Meaning |
|
|
|
MS (message system) | solid green | message link open to the system |
|
|
|
| off | message link not open to the system |
|
|
|
ST (status) | flashing | operational |
|
|
|
| off | not operational |
|
|
|
| solid | card is booting |
|
|
|
L0 and L1 | right side - solid red | error |
|
|
|
| right side - off | no error |
|
|
|
| left side - solid green | |
|
|
|
| left side - flashing green | Layer 1 established |
|
|
|
| left side - off | no link |
|
|
|
| right side - yellow | alarm indication from far end |
| with left side - flashing green |
|
|
|
|
| right side - yellow | blue alarm from card - normal during |
| with left side - off | link startup |
|
|
|
Release 3.3 | 255 |