Installing
you must align with a slot on the FIM connectors. Lock each connector into position by pushing its metal collar forward and clipping it onto the FIM connector.
7.Push the Peripheral Slot FIM Carrier fully into the slot and secure it with the card latch.
8.Remove the
9.Route the fiber optic cables from the Peripheral Cabinet to the SUPERSET HUB.
10.Replace the Peripheral Cabinet front and rear panels.
Note: For more information, see Fiber Interface Module (FIM).
Install the SUPERSET HUB
To install the SUPERSET HUB unit:
1.Attach the rubber feet to the base of the unit.
2.If required, secure the mounting brackets to the SUPERSET HUB case by using the holes appropriate to the selected mounting position and install the unit in an equipment rack or mount the unit on a wall. Note: The side which contains the row of
3.Ensure that the ventilation holes are not blocked.
4.Remove the black plastic dust caps from the fiber optic cables and from the connector ferrules on the unit.
5.Connect the fiber optic cables from the Peripheral Slot FIM Carrier in the Peripheral Cabinet to the connectors on the SUPERSET HUB unit.
6.Connect the
7.Connect the power cable to a convenient wall socket. Note: The wall socket is the main disconnect device and must, therefore, be installed near the unit and be easily accessible.
8.Program the peripheral devices.
Note: Program the SUPERSET HUB as a DNI Line Card in the slot where the Peripheral Slot FIM Carrier is inserted.