Mitel manual Music On Hold 3300 Universal ASU only, LS Trunk Parameters 3300 Universal ASU

Models: 3300

1 266
Download 266 pages 28.26 Kb
Page 78
Image 78

3300 ICP Hardware User Guide

LS Trunk Signaling Protocols (3300 Universal ASU)

LS Trunk Signaling Supported Protocols

ASU Variant

LS Protocol

 

 

North America (NA)

TIA/EIA-464-B

Latin America (LA)

 

 

 

United Kingdom (UK)

UK Subscriber / Subsidiary Loop

 

 

United Kingdom (UK)

UK Loop Start Disconnect Clear

 

 

United Kingdom (UK)

CTR-21

Europe (EU)

 

 

 

LS Trunk Parameters (3300 Universal ASU)

 

Trunk Functions

Parameters for NA/LA

Parameters for UK/EU

 

 

 

Input Impedance

600 Ohms

370R + (620R//310uF) (UK)

 

 

270R + (750R//150uF) (EU)

 

 

 

Balance Impedance

600 Ohms for short loop

370R + (620R//310uF) (UK) 270R

 

application

+ (750R//150uF) (EU) for all loop

 

350R + (1000R// .21uF) for

lengths

 

long loops

 

Min. operating loop current

18mA

18mA

 

 

 

Max operating loop current

100mA

60mA

 

 

 

Loop Current Limit

None

60mA

 

 

 

Ring detector Threshold

30Vrms

20Vrms

 

 

 

Dummy Ringer load

10kOhms + 2.2uF (NA)

10kOhms + 2.2uF

 

65Ohms + 2.2uF (LA)

 

 

 

 

Reversal detector

Detects CO battery polarity

Detects CO battery polarity

 

 

 

Loop detect for CO disc. (no

< 2V across Tip and Ring

< 2V across Tip and Ring

battery)

 

 

 

 

 

Meter Pulse Detection

None

50Hz longitudinal (UK)

 

 

None (EU)

 

 

 

Note: The NA variant is designed according to the performance standard EIA/TIA 464C. The UK Variant is designed in accordance with CTR21, but has design parameters favoring towards BS6305 and BS6450. The EU variant is designed in accordance with CTR21.

Music On Hold (3300 Universal ASU only)

Four physical ports are supported for Music on Hold (MOH) on the 3300 Universal ASU.

The MOH interface supports the following features:

600 Ohm input impedance

Signal level overload protection as mandated by FCC part 68 on encoded analog content

Dry Tip/Ring interface (no battery)

Always active input (no external control required or provided).

70

Release 3.3

Page 78
Image 78
Mitel manual Music On Hold 3300 Universal ASU only, LS Trunk Parameters 3300 Universal ASU, ASU Variant LS Protocol