3300 ICP Hardware User Guide

2.Unpack the CEPT Interface Assembly. Inspect it to ensure that it is not damaged.

3.Set the CEPT Interface Assembly jumpers to the desired positions.

4.Locate the slot in the DSU box that corresponds to the DSU slot that holds the CEPT Formatter card. When you are facing the rear panel, the DSU box slots, from right to left, correspond to DSU slots 3/1/2 to 3/1/5, or on an SX-2000 DSU node correspond to DSU slots 2 to 5.

5.Remove the cover plate from the slot on the metal box by unscrewing the two screws that hold it in place.

6.Insert the CEPT Interface Assembly into the empty slot in the DSU box, and plug it into the DIN connector in the back of the DSU box.

7.Align the screw holes on the CEPT Interface Assembly faceplate with the screw holes in the metal box, and fasten the faceplate to the box.

8.Connect the cables from the external network to the BNC connectors on the CEPT Interface Assembly.

9.Remove the anti-static strap from your wrist.

Install Wireless Devices

To install a wireless device:

1.Symbol Technologies will complete a site survey.

2.Symbol Technologies will install and configure the Air Access Points.

3.Complete Programming on 3300 ICP.

4.Install the Symbol NetVision MiNET Phone Administrator Tool on a Windows NT or Win- dows 2000 PC.

5.Upgrade the Symbol phone firmware to use the MiNET protocol. Refer to the Symbol NVP II MiNET Update Procedure located in the Hardware User Guide.

6.Configure the wireless phones using the Symbol NetVision MiNET Phone Administrator Tool.

Note: To migrate from a 3200 ICP or 3800 WAG the wireless network must use the Direct Sequencing (D.S.) Spread Spectrum using the 802.11b protocol. The wireless phones must have new firmware downloaded.

Install Symbol NetVision MiNET Phone Administrator Tool

The tool is found on the 3300 ICP software CD and must be installed on a PC that is running Windows NT or Windows 2000.

To install the tool:

1.Insert the software CD into the CD-ROM drive.

2.Click \3rd_Party\Wireless\Administration_Tool \MiNET<xxx>.exe.

3.Click UnZip to place files in C:\temp\symbol.

4.Click Close.