Alarm Operation
Alarm Operation
Note: The following system dependent features apply to the 5624 Personal Alarm license only. See the Mitel 5624 Wireless Handset Configuration Guide.
Push-button Alarm
Send Personal Alarm
You press the red alarm button twice within two seconds to activate the alarm. By default the text “Personal Alarm” appears. The alarm is sent to the alarm centre that distributes it further. After that the handset returns to
Send Test Alarm
If you press and hold the red alarm button until the (default) “Test Alarm” text appears the following occurs depending on the options specified:
•A beep is heard.
•The orange LED flashes twice.
•The vibrator stirs.
•The handset receives a notification that the alarm has been received by the system.
•If configured, the Acoustic Location Signal (ALS) is activated after the alarm has been sent, or a call is established to a
If the parameter "Silent alarm" is set, ALS will not be triggered and you will not be notified that the alarm was sent.
•information about the handset’s location is sent along with the alarm.
Man-down and No-movement Alarm
The
The handset alerts by beep, vibrator and LED signals, depending on the settings, during a predefined period of time (default 7 seconds). At the same time the handset displays the message
The handset then sends the alarm, unless the alarm is cancelled. The handset will confirm that the alarm has been sent by beep, vibrator and LED signals. In addition the handset displays the message