AUTO SET UP (continued) / Initial settings

The <RECORD SETTING> screen consists of 2 pages. The second page is displayed when turning the JOG dial to move the cursor to “NEXT PAGE”, and turn the SHUTTLE ring clockwise.

<RECORD SETTING> 1/2

Camera selection during alarm recording

<RECORD SETTING> ALARM CH

NO

PPS

GRADE

A-PPS

A-GRADE

>> 1

12.5P

SUPER

12.5P

SUPER

2------ SUPER ------ SUPER

3------ SUPER ------ SUPER

4 12.5P SUPER 12.5P SUPER

5------ SUPER ------ SUPER

<ESTD

REC>

D H M

NEXT

PAGE

 

INITIALIZATION

Please perform initialization, when a <INITIALIZATION> setup is changed.

1.Turn ON the MAIN switch on the rear of the unit, and wait until the ACCESS indicator goes off. Hold down the REC/STOP button, and press the POWER button on the front of the unit.

The unit starts-up, and the <INITIALIZATION> screen is appears.

POWER button operation will not be accepted while the ACCESS indicator is flashing. Press the POWER button after the indicator turns off.

2.Select “INITIALIZATION” by turning the JOG dial, and turn the SHUTTLE ring clockwise.

The setting is made, and the display returns to normal after initialization.

<RECORD SETTING> 2/2

<RECORD SETTING>

A-GRADE

NO

PPS

GRADE A-PPS

>> 6

------

SUPER

------

SUPER

7

12.5P

SUPER

12.5P

SUPER

8------ SUPER ------ SUPER

9------ SUPER ------ SUPER

<ESTD REC>

D H M

PRESS POWER BUTTON TO EXIT

According to the number of the cameras connected and the value of “RECORDING CYCLE”, the most suit- able setting of the “PPS”, “A-PPS”, “GRADE” and “A- GRADE” are set automatically.

12.When the setting is complete, press the POWER button.

“SETTING UP...” is displayed on the screen, and the unit starts-up.

To execute AUTO SET UP again, press and hold the camera number button 1 and press the POWER button, when the MAIN switch is set to ON and the POWER button is set to OFF. The <CAMERA CHECK> screen appears. However all menu of record setting will be reset.

INITIALIZATION

The <INITIALIZATION> setting is used to select the mode of peripheral recording devices connected to SCSI connector ID4ID5, to make HDD SETTING, and to initialize the HDD.

HDD SETTING

The HDD SETTING can be set to MIRRORING (simulta- neous recording to the internal HDD as a pair), PARTITION (an independent partition that can be set within the total HDD memory specifically for ALARM RECORDING). ( see pages 74,75 “MIRRORING”, “PARTITION”)

<INITIALIZATION>

NORMAL

>>HDD SETTING

POWER OFF

INITIALIZATION

Settings are not confirmed unless you perform

“INITIALIZATION”.

Performing “INITIALIZATION” initializes all data on the HDD. It deletes the complete ALARM LIST, and the next entry is registered from 00001.

Select “POWER OFF” to abort initialization.

ALL DATA WILL BE ERASED

WHEN PROCEED INITIALIZATION

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

AUTO SET UP / Initial settings

18

Page 18
Image 18
Mitsubishi Electronics DX-TL950E operation manual Auto SET UP / Initial settings, Initialization, HDD Setting