<INITIAL SET UP/INFORMATION> (continued)

Setting ( default : “OFF” )

“REMAIN”, “WARNING”, “ALARM”, “OFF

SETTING

REMAIN

WARNING ALARM OFF

BUZZER

 

 

 

 

 

 

 

 

 

When reaching the remaining

ON

OFF

OFF

OFF

capacity set in “REMAIN HDD”

 

 

 

 

 

 

 

 

 

When a failure occurs and

OFF

ON

OFF

OFF

a warning is displayed

 

 

 

 

 

 

 

 

 

When an alarm recording or

OFF

OFF

ON

OFF

emergency recording is started

 

 

 

 

 

 

 

 

 

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } Select “BUZZER” in the <REAR TERMINAL SETTINGS> screen. Display the desired setting and confirm.

2.Turn the SHUTTLE ring counterclockwise or press the SET UP button.

REMAIN HDD

A warning indicating that the either remaining capacity of HDD has become low during recording is outputted. The device can be selected and the remaining capacity can be set here.

<REAR

TERMINAL SETTINGS>

OFF

MODE

OUT

1

 

MODE

OUT

2

 

OFF

MODE

OUT

3

 

OFF

MODE

OUT

4

 

OFF

MODE

OUT

5

 

OFF

KEY SOUND

 

 

ON

BUZZER

 

 

OFF

>>REMAIN HDD

MAIN-10%

CALL OUT SETTINGS

 

10M

EMERGENCY REC DURATION

A warning is outputted using the following methods when the remaining capacity becomes low during re- cording.

The HDD usage display flashes when “3” is set to “DISPLAY MODE” in the <TIME DATE/DISPLAY SET- TINGS> screen.

A buzzer will sound when “REMAIN” is set to “BUZZER” in the <REAR TERMINAL SETTINGS> screen.

Setting of DEVICE ( default : “MAIN” )

“MAIN” : Displays a warning of low MAIN HDD capacity.

“SUB” : Displays a warning of low SUB HDD capacity.

“OFF” : Does not display warning of low capacity.

“SUB” is appeared when “PARTITION” is selected on “HDD SETTING” of the <INITIALIZATION> screen.

Setting of “REMAIN HDD” ( default : “10%” )

“2%”, “4%”, “6%”, “8%”, “10%”, “15%”,“20%”, “30%”, “40%”, “50%”

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } “Select “REMAIN HDD” in the <REAR TERMINAL SETTINGS> screen and turn the SHUTTLE ring clockwise twice.

The setting display reverses in color when the SHUTTLE ring is turned the first time. When the ring is turned for the second time, the background turns red and flashes.

2.Turn the JOG dial to display the desired device and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

3.Turn the JOG dial clockwise to move the reversed display to the REMAIN HDD value and turn the SHUTTLE ring clockwise.

The background of the REMAIN HDD value turns red and flashes.

4.Turn the JOG dial to display the desired capacity and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

5.Turn the SHUTTLE ring counterclockwise or press the SET UP button.

CALL OUT SETTINGS

The CALL OUT setting is a setting to notify to the out- side warning signals outputted by this device by outputting the signals from the CALL OUT terminal on the rear.

CALL OUT SETTINGS use photo-coupler output to decrease the amount of malfunctions due to wiring. See page 15 “CALL OUT Output terminal” for apt connection procedures.

• HDD MAIN REMAIN/HDD SUB REMAIN

When the remaining memory in the HDD reaches the set value, the unit outputs a signal from the CALL OUT terminal, and the “REC/REM” warning displayed on the screen.

<CALL OUT

SETTINGS>

OFF

>>HDD

MAIN

REMAIN

HDD

MAIN

FULL

OFF

HDD

SUB REMAIN

OFF

HDD

SUB FULL

OFF

“HDD SUB REMAIN” is appeared when “PARTITION” is selected on “HDD SETTING” of the <INITIALIZATION> screen.

Setting ( default : “OFF” )

“2%”, “4%”, “6%”, “8%”, “10%”, “15%”, “20%”, “30%”, “40%”, “50%”, “OFF

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } <REAR TERMINAL SETTINGS> } Select “HDD MAIN REMAIN” or “HDD SUB REMAIN” in the <CALL OUT SETTINGS> screen. Display the desired setting and confirm.

2.Turn the SHUTTLE ring counterclockwise or press the SET UP button.

By pressing the WARNING RESET button, the HDD capacity warning from the CALL OUT terminal can be cancelled.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

•••••••••••••

50

Page 50
Image 50
Mitsubishi Electronics DX-TL950E Setting of Device default Main, Setting of Remain HDD default 10%, Call OUT Settings