Points to be aware of regarding MIRROR mode

Performing RESTORE restores identical data to both HDD master and HDD slave.

Performing “MAIN HDD DATA CLEAR” in “MIR- RORING” mode deletes all data in both HDD.

In the event of a HDD master/HDD slave malfunc- tion, HDD master/HDD slave items are registered separately on the <WARNING LOG LIST>.

In the event that either HDD maste or HDD slave malfunction, the “MIRROR” warning is displayed, and the operable HDD continues the recording. Press the WARNING RESET button on the front of the unit to reset the “MIRROR” warning.

The “MIRROR” warning is displayed every time the unit is started-up until the faulty HDD is re- placed.

Automatic data archive commences at start-up after replacement with an operational HDD.

If any HDD of each HDD master and HDD slave malfunction simultaneously, the data can not be repaired.

Ask at place of purchase about data restoration when repairing/replacing a faulty HDD.

PARTITION/PARTITION SIZE

PARTITION mode only uses the internal HDD. PARTITION mode designates the area inside the HDD that is specified as each HDD’s sub-device capacity for Alarm recording. This independent partition inside the HDD allows to keep the data of alarm recording.

The normal recording area is referred to as “MAIN”, and the alarm recording area (PARTITION area) is re- ferred to as “SUB”.

1.Turn ON the MAIN switch on the rear of the unit, and wait until the ACCESS indicator goes off. Hold down the REC/STOP button, and press the POWER button on the front of the unit.

The <INITIALIZATION> screen is displayed.

POWER button operation will not be accepted while the ACCESS indicator is flashing. Press the POWER button after the indicator turns off.

2.Select “HDD SETTING” by turning the JOG dial, display “PARTITION”, and turn the SHUTTLE ring clockwise.

The “PARTITION SIZE” setting appears on the <INITIALIZATION> screen.

<INITIALIZATION>

PARTITION

>>HDD SETTING

PARTITION SIZE

10%

POWER OFF

 

INITIALIZATION

 

3.Display the desired device capacity, and turn the SHUTTLE ring clockwise.

The setting is made.

Setting of “PARTITION SIZE” ( default : 10% )

10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90%

The storage area in MAIN HDD set in “PARTITION” is displayed with the percentage(%) and the record- able time of that storage area is displayed in “<ESTD REC>”.

7

2.5P

STD

2.5P

STD

8

2.5P

STD

2.5P

STD

9

2.5P

STD

2.5P

STD

<ESTD REC>

 

D H M

%

4.Select “INITIALIZATION” by turning the JOG dial, and turn the SHUTTLE ring clockwise.

The setting is made, and initialization commences.

Settings are not confirmed unless you perform

“INITIALIZATION”.

Initialization deletes all data in the HDD.

Points to be aware of regarding PARTITION mode

Either “MAIN” or “SUB” can be selected for copy.

Playback, search, information display, REMAIN HDD, CALL OUT, and data delete functions are performed independently for “MAIN” and “SUB”.

When “HDD REPEAT REC SUB” is set to “OFF”, and all memory in SUB HDD is used, the record- ing stops. Afterwards, the indicator will blink when an alarm enters, but no recording will be performed.

When at the time of “ALARM CH” use an alarm signal enters to a camera number not set for nor- mal recording, pre-alarm recording may not be performed in some cases.

ENGLISH

ALL DATA WILL BE ERASED

WHEN PROCEED INITIALIZATION

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

75

Page 75
Image 75
Mitsubishi Electronics DX-TL950E operation manual Points to be aware of regarding Mirror mode, PARTITION/PARTITION Size