Mitsubishi Electronics FX1S manual Battery Backed/ Latched State Relays, PLC FX 1S FX 1N FX 2N

Models: FX1S

1 120
Download 120 pages 31.35 Kb
Page 81
Image 81

FX Series Programmable Controllers

Devices in Detail 4

4.4.2Battery Backed/ Latched State Relays

There are a number of battery backed or latched relays whose status is retained in battery backed or EEPROM memory. If a power failure should occur all output and general purpose relays are switched off. When operation is resumed the previous status of these relays is restored.

Available devices:

 

 

 

 

 

 

 

 

 

PLC

FX1S

FX1N

FX2N

 

FX2NC

 

 

General state

N/A

N/A

 

500

 

 

relays

 

(S0 - 499)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery backed/

128

1000

 

500

 

 

latched relays

(S0 - 127)

(S0 - 999)

(S500 - 999)

 

 

 

 

 

 

 

 

 

Total available

128

1000

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• For more information about device availability for individual PLC’s, see chapter 8.

External loads:

State relays are provided with countless number of NO contact points and NC contact points, and are freely available for use through out a PLC program. These contacts cannot be used to directly drive external loads. All external loads should be driven through the use of direct (ex. Y) outputs.

4-7