5.Pull the lamp out of the projector by the handle.
•Pull the lamp out of the projector slowly and carefully. When the bulb has exploded, rough removal of the lamp may cause glass fragments to scatter.
•Do not spill water on the lamp, or do not place it where children can reach or near flammables. You may get burned or injured.
6.Hold the handle of the new lamp and insert the lamp in the opening in the projector to the end in the correct orientation.
7.Press the handle into its storing position.
•Make sure that the handle is securely locked.
8.Tighten the three fixing screws (b) securely using a flatblade driver.
9.Mount the lamp cover on the projector and fix the lamp cover fixing screw (a) securely using a hexagon wrench
•When the lamp cover is not mounted correctly, the projector is not turned on.
ENGLISH
How to reset the lamp operating time
1.Display the OPTION menu.
2.Select LAMP HOUR by pressing the { or } button.
3.Press the ENTER button.
•The LAMP HOUR menu appears.
4.Select LAMP RESET by pressing the $ or % button.
5.Select YES by pressing the { or } button.
6.Press the ENTER button.
•The lamp operating time is reset. To cancel the menu:
7.Press the MENU button.
•When the lamp operating time has exceeded 1500 hours, a warning indication is kept displayed on the screen even after the lamp is replaced until the lamp operating time is reset.
•Do not reset the lamp operating time unless you replace the lamp.
•The lamp in this product contains mercury. Please dispose of properly.