Indicators

Indicators

This projector has two indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your

dealer.

STATUS indicator POWER indicator

Normal condition

POWER

STATUS

CONDITION

NOTE

Steady

 

Stand-by

 

Off

 

 

red

 

 

 

 

 

Steady

Blinking

Lamp stand-by (about 1 minute)

The POWER button cannot be used to

 

switch between on and off.

green

green

 

 

 

Steady

Steady

The power is on. (Normal condition)

 

 

 

green

green

 

 

Abnormal condition

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

 

 

 

 

 

 

 

Abnormal temperature

 

 

 

 

 

 

 

 

• The ventilation grilles are clogged with dust or dirt.

• Clean the ventilation grilles.

green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The room temperature is high.

• Relocate the projector to a cooler place.

or

 

 

 

 

 

 

 

Blinking orange

 

 

 

 

 

 

 

Steady

 

 

 

 

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The protection circuit is working or the lamp is in an

• Wait until the STATUS indicator goes out,

Steady

 

 

 

 

 

 

 

abnormal condition.

then press the POWER button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking green

 

• If the above solution is not effective,

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replace the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation

Replace the lamp.

 

 

 

 

 

 

 

Blinking green/red

time reached 3750 hours*1 while the power was on.)

Change with a new lamp if this problem

green

 

 

 

 

 

 

 

 

recurs.

Steady

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking red

time reached 3750 hours*1 while the power was off.)

 

red

 

 

 

 

 

 

 

 

 

Steady

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation

 

Steady red

time reached 5000 hours*1*2 while the power was off.)

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The lamp cover isn’t closed.

Close the cover correctly.

 

 

 

 

 

 

 

 

 

 

 

 

Blinking

Off

 

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Abnormal.

Contact your dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking

 

or

 

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be shorted.

*2 Duration when LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours.

EN-43