ALARM RECORDING

It is possible to switch from all recording modes to the 3H - L24H recording mode by applying an alarm signal to the SET IN terminal on the rear panel.

ALARM SET INPUT

3H - 960H, 0H

3H

3H - L24H

RECORDING

RECORD-

RECORDING

 

 

ING

 

 

 

 

 

 

 

 

 

15sec

 

NORMAL mode

 

 

ALARM mode

 

 

 

 

 

 

3H - 960H, 0H

RECORDING

NORMAL mode

It is possible to switch to the alarm recording by ap- plying the set signal from the alarm sensor during re- cording in 3H,L12H, L24H, 48H - 960H or 0H mode.

Set the alarm recording mode and alarm recording period with the “RECORDING SET UP” menu. (See page 10.)

The index signal is automatically recorded when an alarm recording begins. (INDEX indicator flashes on the fluorescent display.)

To record the index signal, the first 15 seconds of the alarm recording are in 3H mode.

While the index signal is being recorded (for 15 seconds), if another set signal is applied to the SET IN terminal, it will not trigger a new alarm recording.

 

ALARM RECORDING CONNECTION

 

 

 

Alarm set

External alarm lamp

• The alarm can be confirmed from a distance by

switch

or buzzer

connecting the ALM (ALARM) OUT terminal to

 

 

 

 

 

 

an existing alarm system panel or other external

 

 

devices such as a buzzer.

SET

RST

REC

GND

ALM

MODE

CLK

CALL

 

IN

 

 

 

 

OUT

RESET

 

 

 

 

 

 

 

IN OUT

S-VIDEO

MIC

IN

OUT

IN

REMOTE

 

 

AUDIO

OUT

 

 

 

 

VIDEO

Alarm reset switch

EXTERNAL TIME CLOCK ADJUSTMENT

*1

SET

RST

REC

GND

ALM

MODE

CLK

CALL

 

IN

 

 

 

 

OUT

 

1st VCR

SET

RST

REC

GND

ALM

MODE

CLK

CALL

 

IN

 

 

 

 

OUT

 

2nd VCR

If the “ALARM REC DURATION” of the “RECORDING SET UP” menu is set to other than “MAN1”, the on-screen clock can be reset to the nearest hour, by applying a signal to the RST (RESET) IN terminal. For example, if the current time is 11:29:59, it will be reset to 11:00:00; and if the current time is 11:30:00, it will be reset to 12:00:00.

*1: When connecting the MODE terminal of the 1st VCR with RST (RESET) IN terminal of the 2nd VCR and if the “MODE OUT” of the “REAR TERMINAL” menu is set to “CLOCK ADJ”, the on-screen clock of the 2nd VCR will automatically be adjusted to that of thet1s VCR.