Mitsubishi Electronics VS-60609 service manual Size Length, Table a

Models: VS-60609

1 71
Download 71 pages 60.21 Kb
Page 10
Image 10

MODELS: VS-45609 / VS-50609 / VS-55609 / VS-60609 / VS-60719 / VS-70709

2. Installation of the Lenticular Screen and Fresnel Lens

Note: Store the Lenticular Screen and Fresnel Lens in a cool dry place. High humidity may deform the Lenticular Screen and Fresnel Lens.

1.Apply double coated tape (Part # LENS-TAPE) along the top front edge of the Fresnel Lens as shown in figure 3-2. Refer to Table A for proper tape length.

2.Place the Fresnel Lens on top of the Lenticular Screen and apply pressure at the top edge to bond them together as shown in figure 3-2.

3.Install CUSHION-CORNER pads at the bottom corners on the back of the Fresnel Lens, as shown in figure 3-3.

Fresnel Lens

 

 

Top

Fresnel

Lenticular

 

 

Lens

Screen

( * X ) inch

 

 

Top

 

 

Double Sided Tape

 

0.16 inch

(Part# LENS-TAPE)

 

Bottom

Bottom

Lenticular Screen

Figure 3-2

 

 

 

 

Top

* Tape Application Guide

 

 

 

 

 

 

 

MODEL

SCREEN

TAPE

 

Fresnel Lens

SIZE

LENGTH

 

 

 

(Rear)

 

 

 

 

VS-45609

45"

36"

 

 

 

 

 

 

 

VS-50609

50"

40"

 

 

VS-55609

55"

44"

 

 

 

 

 

 

Bottom

VS-60609

60"

48"

 

 

 

 

 

VS-60719

60"

48"

 

CUSHION-CORNER(B)

VS-70709

70"

56"

 

Part #622D757060

Table A

CUSHION-CORNER(A)

Part #622D757050

Figure 3-3