MODELS: VS-45609 / VS-50609 / VS-55609 / VS-60609 / VS-60719 / VS-70709

Items in the table below are set to following after Initalization.

AV MEMORY

AV MEMORY

All Inputs

TINT

31

COLOR

31

CONTRAST

63

BRIGHTNESS

31

SHARPNESS

31

COLOR TEMP

HIGH

BASS

31

TREBLE

31

BALANCE

31

SURROUND

OFF

LEVEL SOUND

OFF

4. LED Indicator Diagnostics

The “Power ON LED” provides an indication of the sets operation, and the possible cause of a malfunction.

1.Initial Control Circuitry Check

Immediately after the TV is connected to an AC power source:

The LED flashes three times ... indicating the Microprocessor has initialized and is functioning properly.

If the LED does not flash ... the Microprocessor is NOT functioning.

2.Error Code Operational Check

Pressing the front panel “INPUT” and “MENU” buttons at the same time, and holding for 5 seconds, activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem

has occured since the last Initalization.

Note: The front panel buttons must used, NOT those on the Remote Control.

The number of flashes indicates the value of the MSD (tens digit) of the Error Code.

The flashing then pauses for approximately 1/2 second.

The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.

The Error Code is repeated a total of 5 times.

Example: If the Error Code is “24”, the LED will flash two times, pause, and then flash four times.

3.Error Codes

The Error Code designations indicating a malfunction, or no malfunction, are listed below: “12” ... indicates no error has occured.

“21” ... X-Ray Protect circuit. “22” ... Short Protect circuit.

“23” ... Horizontal Deflection failure. “24” ... Vertical Deflection failure.

Page 19

Page 19
Image 19
Mitsubishi Electronics VS-60609 AV Memory, LED Indicator Diagnostics, Initial Control Circuitry Check, Error Codes