[CRT Circuit]

 

 

Purpose:

To set the CRTs white level at Low Color Temperature.

9. White Balance

Symptom: Monchrome has a color tint.

(Low Color Temperature)

 

 

 

 

 

 

 

 

Measuring

--------

 

Note: This adjustment should be performed after the High temperature White

Instrument

 

 

 

Test Point

--------

 

Balance Adjustment.

 

 

 

 

 

 

 

Low Color Temperature White Balance

Ext. Trigger

------

 

 

1. Supply a Full White Raster signal to the Video Input.

 

 

 

 

Measuring

-------

 

 

2. Enter the Service Mode, VCJ Function.

Range

 

 

 

3. Adjust Item “17 RDRL” and “18 BDRL” for optimum white at the center of the

Input Signal

Full White Raster

picture.

 

 

Input Terminal

Video Input

Note: If the Cutoff level changes during the adjustment, use Items “14 CTRL”

 

and “16 CTBL” to touch up the Cutoff level. Then readjust “RFRL” and

 

 

 

 

 

 

 

 

 

 

“BDRL”.

 

 

 

 

4. Save data and exit the Service Mode.

 

 

 

 

 

 

SERVICE MODE

 

 

 

 

Activate …….. MENU-0-1-5-7

 

 

 

 

Function …...………..AUDIO

 

 

 

 

Item No. ……….…….VIDEO

 

 

 

 

Adjus t Data ….…….ADJUST

 

 

 

 

Save Data …. ………ENTER

 

 

 

 

Exit …………..MENU (twice)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Video Circuit]

Purpose:

To set black level of the picture.

10. Black Level

Symptom:

Excessive or insufficient contrast.

Measuring

--------

Instrument

 

Test Point

--------

 

Ext. Trigger

------

Measuring

-------

Range

 

Input Signal

Monoscope

Input Terminal

Video Input

Note: This adjustment should be performed after the Cutoff and White Balance Adjustments.

1.Supply a Monoscope signal to the Video Input.

2.Enter the Service Mode, VCJ Function.

3.Adjust Item “7 BRTH” so the 0% and 10% gradation levels on the Mono- scope pattern are the same. (Data should be within 31 ±4 range)

4.Save the data and exit the Service Mode.

SERVICE MODE Activate …….. MENU-0-1-5-7

Function …...………..AUDIO

Item No. ……….…….VIDEO

Adjust Data ….…….ADJUST

Save Data …. ………ENTER

Exit …………..MENU (twice)