ELECTRICAL ADJUSTMENTS

Note: Perform only the adjustments required.

Do not attempt an alignment if proper equipment is not available.

1.Test Equipment

Oscilloscope (Unless otherwise specified, use 10:1 probes)

Signal Generator

Frequency Counter

Direct Current Voltmeter Direct Current Power Supply

Multiplex Audio Signal Generator

Direct Current Ampere Meter

2.Test Signal

A. Monoscope Signal

Note: If you do not have

a monoscope signal source, connect the unit to a VCR and play a Monoscope *alignment tape.

(* Part Number: 859C568060)

B. Color Bar Signal

Use the color bar signal shown below, unless otherwise specified in this manual.

Monoscope Signal

100%

75%

40%

40%

1H

Split-Field Color Bars (100% window)