Mitsubishi Electronics VS-60609 service manual Cb, Cr Circuit Purpose, 13. Cb, Cr Offset Symptom

Models: VS-60609

1 71
Download 71 pages 60.21 Kb
Page 34
Image 34

MODELS: VS-45609 / VS-50609 / VS-55609 / VS-60609 / VS-60719 / VS-70709

[Cb, Cr Circuit]

Purpose:

To match the match grays between color and monochrome

13. Cb, Cr Offset

Symptom:

pictures.

Grays have a color tint.

 

 

 

 

 

 

 

Measuring

-----

 

1.

Supply an NTSC White Raster with 25% luminance.

Instrument

 

 

 

Test Point

-----

 

2.

Activate the Service Mode, VCJ Function.

 

3.

Set the data for item “30 COLH” to 63.

 

 

 

 

Ext. Trigger

------

 

4.

Adjust items “23 CBOF” and “24 CROF” for optimum gray.

 

 

 

 

5.

Set the data for item “30 COLH” back to 31.

Measuring

-----

 

 

6.

Save the data and exit the Service Mode.

Range

 

 

 

 

 

 

Input Signal

White Raster @ 25%

 

 

 

 

 

 

 

 

 

 

Input Terminal

NTSC Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SERVICE MODE

 

 

 

 

 

Activate …….. MENU-0-1-5-7

 

 

 

 

 

Function …...………..AUDIO

 

 

 

 

 

Item No. ……….…….VIDEO

 

 

 

 

 

Adjust Data ….…….ADJUST

 

 

 

 

 

Save Data …. ………ENTER

 

 

 

 

 

Exit …………..MENU (twice)

 

 

 

 

 

 

 

 

 

 

 

[On Screen Display Circuit]

Purpose:

To position the on-screen display.

14. Character Position

Symptom:

On-screen display is not positioned correctly.

Measuring

-----

Instrument

 

Test Point

-----

Ext. Trigger

------

Measuring

-----

Range

 

Input Signal

Monoscope

1.Supply a Monoscope signal to the Video or RF Input.

2.Select the Monoscope as the source for the main picture (Input button).

3.Activate the Service Mode, HR Function.

4.Use the Adjust Right/Left buttons to center the display horizontally. (A = B)

5.Save data and exit the Service Mode.

Input Terminal RF or Video

SERVICE MODE Activate …….. MENU-0-1-5-7

Function …...………..AUDIO

Item No. ……….…….VIDEO

Adjust Data ….…….ADJUST

Save Data …. ………ENTER

Exit …………..MENU (twice)