Mitsumi electronic HD8000 user manual Replacing the lamp continued, To replace the lamp

Models: HD8000

1 49
Download 49 pages 39.82 Kb
Page 40
Image 40
Replacing the lamp (continued)

Replacing the lamp (continued)

To replace the lamp:

(a)

(c)

Handle

(c)

(a)

Important:

1.Turn off the main power switch and unplug the power cord.

2.Reverse the projector gently.

3.Loosen the screw (a) using a Phillips screwdriver (+), and remove the lamp cover (b).

4.Loosen the screws (c) using a Phillips screwdriver (+).

5.Pull up the handle.

6.Pull out the lamp box by the handle while holding the

(b)projector.

Pull the lamp box out of the projector slowly. If it is pulled out quickly, the lamp may break scattering glass fragments.

Do not spill liquid on the removed lamp box or do not place it near any flammable object or where children can reach to prevent injury or fire.

7.Load a new lamp box securely into the projector in the right orientation.

8.Put the handle back to the original position.

Make sure that the handle is locked.

9.Tighten up the screws (c) using a Phillips screwdriver (+).

10.Tighten up the screw (a) using a Phillips screwdriver (+) to secure the lamp cover.

Reset of the lamp operation time

11.Plug the power cord into the wall outlet and turn on the main power switch.

12.Hold down the W, X, and POWER buttons on the control panel at the same time about 3 seconds.

Unless these 3 buttons are held down at the same time, the lamp operation time isn’t reset.

Make sure that the STATUS indicator is lit twice and the lamp operation time is reset successfully.

The projector doesn’t turn on if the lamp cover isn’t attached securely.

Be sure to reset the lamp operation time whenever you replace the lamp.

Do not reset the lamp operation time unless you replace the lamp.

The lamp is fragile. If it is broken, be careful not to cut yourself with glass fragments.

Contact your dealer for a new lamp.

Caution:

This projector uses a lamp that contains mercury. Disposal of the lamp or the projector with the lamp may be regulated due to environmental considerations. For disposal or recycling information, please contact your local authorities or the Electronic Industries Alliance: www.eiae.org. (For the U.S. only.)