Printer Error/Status Codes 9820/9830/9835 Service Manual
July 1998 TC9830SM Rev. B 7/98 Confidential 45
104 Batch mode must be N (new) or U (update).
105 Batch separator must be 0 (Off) or 1 (On) in the batch control field.
106 Print multiple is outside range 1 to 999.
107 Cut multiple is outside range 0 to 999. Only valid for printers with a knife.
108 Multiple part supply is outside range 1 to 5.
109 Reserved for knife usage. Only valid for printers with a knife.
200 Option number must be 1, 4, 30, 31, 42, 50, 51, 52, 60, or 61.
201 Copy length is outside range 0 to 2710.
202 Copy start position must be 1 to 2710.
203 Destination start position must be 1 to 2710.
204 Source field must be 0 to 999.
205 Copy type must be 1 (copy after rules) or 2 (copy before rules).
206 Increment/Decrement selection must be I (increment) or D (decrement).
207 Incrementing start position must be 0 to 2710.
208 Incrementing end position must be 0 to 2710.
209 The incrementing amount must be 0 to 999.
210 Security value for a PDF417 bar code must be 0 to 8. Correct and resend format to printer.
211 Narrow element value is less than 1 or greater than 99. Correct and resend format to printer.
212 Wide element value is less than 1 or greater than 99. Correct and resend format to printer.
213 Dimension must be 1 to 30 for a column or 3 to 90 for a row on a PDF417 bar code.
214 Truncation code must be S (standard) or T (truncated bar code).
215 Aspect code must be C (columns) or R (rows).
216 Option definition must be S (set) or T (template).
217 Input device must be D (Default), H (Host), K (Keyboard), N (None), or S (Scanner).
218 Pad direction must be L (from left) or R (from right).
219 Pad character is outside range 0 to 255.
220 Check digit selection must be G to generate check digit.
221 Primary or secondary price format is outside range 1 to 15.
222 Data type restriction is outside range of 1 to 6.
223 Option is not valid for field.
224 Bar code Interchar gap must be 0 to 99 dots (known as additional character gap with Option 50).
251 Power up mode must be 0 (online) or 1 (offline).
252 Language selection must be 0.
253 Batch separator code must be 0 (off) or 1 (on) in the system setup packet.
254 Slash zero selection must be 0 (standard zero) or 1 (slash zero).
255 Supply type must be 0 (black mark) , 1 (die cut), or 2 (continuous).