Monessen Hearth 36CDVXTRN 36CDVXR Venting, How to Use the Vent Graph, From Rear of Unit, 20012253

Models: 36CDVXTRN

1 44
Download 44 pages 17.07 Kb
Page 13
Image 13
36CDVXR Venting

Twist Lock Pipes

When using MHSC twist-lock pipe, it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joint of any telescopic vent section used in the system.

To join the twist lock pipes together, simply align the beads of the male end with the grooves of the female end, then while bringing the pipe together, twist the pipe until the flange on the female end contacts the external flange on the male end. It is recommended that you secure the joints with three (3) sheet metal screws, however this is not mandatory with twist lock pipe.

To make it easier to assemble the joints we suggest putting a lubricant (Vaseline or similar) on the male end of the twist lock pipe prior to assembly.

 

Male End

Female End

 

Screw Holes

TWL100

Fig. 13

Twist-lock pipe joints.

 

36CDVXR Venting

How to Use the Vent Graph

The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.

1.Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 14) locate the point intersecting with slanted graph line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.Select the indicated dimension, and position the fireplace in accordance with same.

Example A:

If the vertical dimension from the floor of the fireplace is 11’ (3.4 m) the horizontal run to the face of the outer wall must not exceed 14’ (4.3 m).

Example B:

If the vertical dimension from the floor of the unit is 7’ (2.14 m), the horizontal run to the face of the outer wall must not exceed 8¹⁄₂’ (2.6 m).

CDVX Series Direct Vent Gas Fireplace

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical

24

 

 

 

 

 

 

 

 

 

 

 

 

to the

23

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

center of the horizontal vent pipe

dimension from the floor of the unit

20

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

eg: A

 

11

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

eg: B

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

5

6

7

8

9

10

11 12

13 14

15 16

17 18

19

20

 

Horizontal dimension from the outside face of the

wall to the center of the fireplace vent flange

Sidewall vent graph showing the relationship between vertical

and horizontal dimensions for a Direct Vent flue system.

Fig. 14 Sidewall venting graph. (Dimensions in feet)

Rear Wall Venting Applications

*Exterior Outside Wall 7” (178 mm) to 20” (508 mm)

From Rear of Unit *

With this application, the following rigid pipe kits may be used:

7” to 13” (178 - 330 mm) to outside wall: 7TCRVT

13” to 20” (330 - 305 mm) to outside wall: 7TCRVT1320 45° elbow with 20” (508 mm) Starter for corner applica- tions

When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance.

Only MHSC venting components are approved to be used in these applications. (Refer to “Venting Com- ponents” listed for different installation requirements)

The maximum straight out the back horizontal distance between the rear of the appliance and the outside face of the rear wall is 20” (508 mm). The minimum is 7” (178 mm). (Fig. 15)

20012253

13

Page 13
Image 13
Monessen Hearth 36CDVXTRN 36CDVXR Venting, How to Use the Vent Graph, Rear Wall Venting Applications, From Rear of Unit