Monessen Hearth 36CDVXTRN Rear Wall Vent Application, From Rear of Unit * Using Flex Venting Kit

Models: 36CDVXTRN

1 44
Download 44 pages 17.07 Kb
Page 16
Image 16
Rear Wall Vent Application

CDVX Series Direct Vent Gas Fireplace

FP1604

Screw

Flex Vent *Exterior Outside Wall 20” - 32” (508 - 813 mm)

Collar

13” - 20”

(330 - 508 mm)

Screws

24Z\x

(622 mm)

FP1605a

Fig. 21 Bend flex pipe up 90° as close to fireplace as pos- sible.

Corner

FramingDo Not Exceed

45° Bend

Termination

FP1606

Fig. 22 Rear view of corner installation.

Fig. 24 The centerline of the termination must be 24Z\x” (622 mm) off the floor.

3.Proceed with Step 3 of “Rear Wall Vent Application *Exterior Outside Wall 20” to 32” (508-813 mm) from Rear of Unit” section (below).

Rear Wall Vent Application

*Exterior Outside Wall 20” - 32” (508 - 813 mm)

From Rear of Unit * Using Flex Vent Kit

7TCD45KT

1.Determine where the termination is to be installed. (Fig. 25)

2.Locate the hole 27Z\v” (692 mm) off the floor. This is the center line of the termination. Refer to “Rear Wall Installation Twist Lock Pipe” section.

Screw

From Rear of Unit * Using Flex Vent Kit Screws

Flex Vent *Exterior Outside Wall 13” to 20” (330 - 508 mm)

Collar

FP1605

Fig. 23 Secure collar in place, slide termination into collar.

Rear Wall Vent Application

Screw

Flex Vent From Rear of Unit * Using Flex Venting Kit

Collar

20” - 32”

(508 - 813 mm)

Screws

27Z\v

(692 mm)

FP1605a

*Exterior Outside Wall 13” to 20” (330 - 508 mm)

From Rear of Unit * Using Flex Venting Kit

1.Determine the location of the termination. (Fig. 24)

IMPORTANT: Vent must have a 2Z\x” (64 mm) rise for this application.

2.Locate the hole 24Z\x” (622 mm) off the floor. This is the center line of the termination. Refer to “Rear Wall Installation Twist Lock Pipe” section.

Fig. 25 The centerline of the termination must be 27Z\v” (692 mm) off the floor.

3.Mount the flex pipe assembly to the fireplace collars and twist the collar that the flex pipe is attached to onto the fireplace.

4.Once the collar is twisted onto the fireplace collar, secure with a screw through the tab. (Fig. 19)

5.While sliding the fireplace into position, lift up the end of the flex pipe and slip it through the firestop. *Be careful not to extend the flex too much. The flex pipe

16

20012253