Monessen Hearth 36CDVXTRN Rear Wall Vent Installations 45 Flex Vent Pipe, Using Kit 7TCD45KT

Models: 36CDVXTRN

1 44
Download 44 pages 17.07 Kb
Page 15
Image 15
Rear Wall Vent Installations -

Finished

Wall

 

 

Secure with Screw

 

Vent Termination

 

C

 

L

 

22”

 

(559 mm)

 

Firestop

 

FP1005a

Fig. 19

Side view of final unit location.

CDVX Series Direct Vent Gas Fireplace

 

Termination

C

 

L

 

to Floor

Flex Section

29 ” Appliance

56O Collars

(749 mm)

FP1473

Fig. 20 Grasp the vent pipe close to the collar and bend to 45° angle. Do not exceed 45°.

Rear Wall Vent Installations -

45° Flex Vent Pipe

Using Kit 7TCD45KT

NOTE: The corner placement dimensions on Page 5, Figure 1 of the manual must be adhered to! Figures 20 & 21 show general installations. Refer to instructions below for a detailed description of instal- lation.

1.Determine where the termination is to be in- stalled. Locate the center of the hole 29Z\x” (749 mm) off the floor. (Fig. 20)

NOTE: The location of the termination hole must be adhered to!

2.Install the firestop as shown on Page 14.

3.Remove the flex vent and extend the flex vent out to its longest length.

4.Bend the tab on the back of the fireplace up. (Fig. 18)

5.Insert the collar on the flex vent that has the twist lock embosses on it onto the collar of the fire-

place. Twist the collar to “lock it” onto the fireplace. Run a screw through the tab and into the collar to secure the collar onto the fireplace.

6.Bend the flex pipe up 90° as close to the fireplace as possible. (Fig. 21)

7.Slide the fireplace partially into the corner and, while holding the vertical portion of the flex vent pipe, grab the exposed end collar and bend it down to the height of the opening in the wall.

8.While pushing the unit in place, slide the collar through the firestop. NOTE: It may be necessary to trim some material off of the collar. The collar is made long to accommodate brick finished houses. (Fig. 23)

9.Secure the collar in place by running a screw through the tab in the firestop and through the col- lar.

10.Slide the termination into the collar and secure with the 4 screws provided. (Fig. 23)

20012253

15

Page 15
Image 15
Monessen Hearth 36CDVXTRN Rear Wall Vent Installations 45 Flex Vent Pipe, Using Kit 7TCD45KT, 20012253