4DIAGNOSTICS

3.When the desired new frequency has been selected, press the SELECT key to start the search. The manual frequency search will last up to 40 seconds. As the set-top searches, the frequency being searched for will flash on the front panel. On the OSD, the “MAN FREQ” line of text will be cleared, the “HUNT MODE” will display “FIX” to indicate a search on a fixed frequency, and the “OOB FREQ” field will change to the frequency being searched for.

4.If the frequency is found with the proper EMM Provider ID, then the front panel will display the normal OOB receiver status. The OSD “LKC” field will change to display the new frequency.

5.If after 40 seconds the frequency search is not successful, the product will perform a warm reset.

6.To abort a search without waiting the 40 seconds, the POWER key can be pressed to cause an immediate warm reset.

Note: The front panel will display “hunt” after a cold reset from the front panel. This indicates that the product is in a Round Robin Hunt Mode. “hunt” will continue to be displayed until the proper stream is detected.

In-Band Status

This diagnostic displays the in-band status for the last attempted tuned channel. The information is updated every 5 seconds.

32

Page 42
Image 42
Motorola DCH6416 installation manual In-Band Status