4 DIAGNOSTICS

Separable Security

This diagnostic displays information on the CableCARD and CableCard Interface with the DCH.

Field

Description

 

 

CARD Interface

CableCARD Interface is a status indication of the interface between the Host

 

and CableCARD. It will indicate ‘Good’ if no errors were detected, ‘Error’ if

 

there is a problem detected with establishing the CableCARD interface, or

 

‘Unsupported CARD’ if the inserted CableCARD is not an M-Card.

 

 

CableCARD ID

The unique identifier provided by the CableCARD.

 

 

Host ID

The unique identifier in the Host Device Certificate.

 

 

Data ID

A value generated by the CableCARD for the Pairing report.

 

 

 

Validation

UKNOWN if a Validation message was not received by the product.

 

VALID or INVALID as set by the Host Validation Message received

 

 

from the headend.

 

BINDING if the CableCARD is busy with the binding authentication

 

 

process.

 

NOT BOUND if Card validation status in not bound for CableCARD

 

 

reasons.

 

HOST CERTIFICATE INVALID if the status is not bound because

 

 

the Host Certificate was invalid.

 

HOST SIGN FAILED if status is not bound because of failure to

 

 

verify Host’s SIGN.

 

AUTH KEY FAILED if status in not bound because of failure to

 

 

match AuthKey from the Host Device.

 

FAILED if binding failed for other reasons.

 

 

Pairing Rpt Method

Set to ‘MMI’ or ‘Reportback’ as received by a message from the headed, or

 

set to ‘Unknown’ if the headend message was not received.

 

 

MSO Phone Number

MSO Phone Number as configured at the headend.

 

 

 

CableCARD

 

 

 

 

 

36

Page 46
Image 46
Motorola DCH6416 installation manual Separable Security, Field Description