Maintenance and Technical Specifications 3 - 7
Digital Scanner Signal Descriptions
Figure 3-1 illustrates the positions of the cradle’s host port pins.
Figure 3-1
Cradle to Host Pin Assignments
The signal descriptions in Table 3-4 apply to the 10-pin RJ connector on the digital scanner cradle and are for
reference on ly.
Radio Link Bluetooth Class 1/Class 2 (2.4 GHz)
Electrical Safety Certified to UL60950-1, CSA 22.2 No. 60950-1, EN60950-1/IEC60950-1
Input Transient Protection EN301 489-1 Clause 9.4, EN301 489-17 Clause 6 Section 1
EMI FCC Part 15 Class B, ICES-003 Class B, EN 55022 1994 A1:1995 + A2:1997,
Japan VCCI
Table 3-3
Technical Specifications - STB 3478 Cradle (Continued)
Item Description
Table 3-4
Digital Scanner Cradle to Host Pin-outs
Pin IBM Synapse RS-232 Keyboard
Wedge Wand USB Scanner
Emulation
1 Reserved SynClock Reserved Reserved Reserved Jump to Pin 6 DBP
2 Power Power Power Power Power Power Power
3 Ground Ground Ground Ground Ground Ground Ground
4 IBM_A(+) Reserved TxD KeyClock DBP Reserved SOS
5 Reserved Reserved RxD TermData CTS D + Decode
6 IBM_B(-) SynData RTS KeyData RTS Jump to Pin 1 Trigger
7 Reserved Reserved CTS TermClock Reserved D - Enable
8 Reserved Reserved Reserved Reserved Reserved Reserved Reserved
9 Reserved Reserved Reserved Reserved Reserved Reserved Reserved
10 Reserved Reserved Reserved Reserved Reserved Reserved Reserved
Pin 10Pin 1