1 - 6 Symbol LS3478 Product Reference Guide
Connecting a Synapse Cable Interface
Symbol’s Synapse Smart Cables enable interfacing to a variety of hosts. The appropriate Synapse ca ble detects
the host.
Figure 1-5
Synapse Cab le Connection
1. Plug the Synapse adapter cable into the bottom of the scanner cradle, as described in Connecting the Cables
to the Cradle on page 1-5.
2. Align the ‘S’ on the Synapse adapter cable with the ‘S’ on the Synapse Smart Cable and plug the cable in.
3. Connect the other end of the Synapse Smart Cable to the host.
Lost Connection to Host
If scanned dat a does not transmit to the crad le’ s h ost, ensure all ca bles are firm ly inserte d and the powe r supp ly is
connected properly. If scanned data still does not transmit to the host, reestablish connection with the host:
1. Disconnect the power supply from the cradle.
2. Disconnect the host interface cable from the cradle.
3. Wait three seconds.
4. Reconnect the host interface cable to the cradle.
5. Reconnect the power supply to the cradle.
6. Re-establish pairing with the cradle.
Mounting the Cradle
For information on mounting the cradle, refer to the documentation included with the cradle.
NOTE Refer to the Synapse Interface Guide provided with the Synapse cable for more information.
Synapse adapter cable
To scanner cradle
Synapse Smart Cable
To host