3 - 4 Symbol LS3478 Product Reference Guide

Scanner emits short low-short
high- short low-short high beep
sequence while it is being
programmed.
Out of ADF parameter
storage space. Erase all rules and re-program with shorter rules.
Out of Synapse parameter
storage space. Scan ’Set Synapse Defaults’ bar code, from the
appropriate Synapse Interface Guide, for cables
no longer in use and re-program the scanner for
the current host interface.
Scanner emits one short high
beep when it is not in use. In RS-232 mode, a <BEL>
character is received and
Beep on <BEL> option is
enabled.
Normal when Beep on <BEL> is enabled and the
scanner is in RS-232 mode.
Scanner emits short low-short
medium-short high beep
sequence.
Scanner is powering up. Normal when scanner battery is inserted.
Battery does not charge. Cradle is outside the
charging temperature r ange. Charge within the recommended temperature of
32° to 104° F
(0° to 40° C) nominal, 41° to 95° F (5° to 35° C)
ideal.
Table 3-1
Troubleshooting (Continued)
Problem Possible Causes Possible Solutions
NOTE If problems still occur , contact the distributor or contact Motorola Enterprise Mobility Support. See page xv