others it may stand for 7-data-bit, even-parity. So, please examine the “getty default” file carefully, and make sure the terminal settings is the same. Otherwise, garbled data will be inevitable.

Advanced Configuration

In the [Advanced configuration] dialog, users can set baud rate mapping, Rx FIFO trigger level, Tx FIFO trigger level and RTS/CTS hardware flow control.

Baud Rate Mapping

There are two different baud rate tables can be selected: High Band and Low Band. The highest baud rate for High Band is 921.6K bps, while 38.4K bps for Low Band. Because of the limit of UNIX termio/termios definition, the highest baud rate label is B38400 (mapped to 38.4K bps). If users wish to use the baudrate higher than 38.4K bps for MOXA boards, this baud rate will be re-mapped to the lower as defined in the below baudrate-mapping table:

3-30Smartio C168H/HS User’s Manual

Page 52
Image 52
Moxa Technologies C168HS user manual Advanced Configuration, Baud Rate Mapping