Connection Option (Opt8x) and Cable Wiring
RS-422/485  Impedance Matching
For 
The value of the termination resistor should equal the characteristic impedance of the transmission line. The resistors should be added near the receiving side.
Opt8J/F/Z  | 
  | 
  | ||
3  | TxD+(B)  | 
  | 
  | RxD+(B)  | 
  | 
  | |||
16  | 
  | 
  | ||
  | ||||
2  | RxD+(B)  | 
  | 
  | TxD+(B)  | 
  | ||||
14  | 
  | 
  | ||
  | ||||
5  | RTS+(B)  | 
  | 
  | CTS+(B)  | 
  | 
  | |||
Opt8J only 13  | 
  | 
  | ||
  | 
  | |||
4  | CTS+(B)  | 
  | 
  | RTS+(B)  | 
  | 
  | |||
19  | 
  | 
  | ||
  | 
  | |||
Note:
1.
 Stands for termination resistor near the receiving side
2.The suggested termination resistor for AWG #26 cable is 100 ohm.
3.The suggested termination resistor for phone cable is 600 ohm.
Smartio C168H/HS User’s Manual