System Configuration
size = 30%, then the system will only detect the motion of objects that occupy an area larger than 30% of the total monitored area; the motion of objects with size less than 30% of the monitored area will NOT be detected.)
2.Sensitivity sets the measurable difference between two sequential images to indicate motion.
A larger object size and lower sensitivity will cause the VPort to ignore small variations in images. When the motion amplitude of some objects in the monitored screen exceeds the settings, a white letter M with red background color will appear in the
Motion detection is provided as a reference because it is
Before completing the Video configuration, 3 items need to be confirmed.
Modulation
There are 3 types of Modulation. Administrators can set the
Although the analog cameras have 2 different standards, NTSC or PAL, all of the cameras connected to VPort 2140 Video Server should use the same standard.
Default Video Source
Administrators can set the default viewing mode for web home page in camera 1, 2, 3, 4, or all in quad.
Save the modification
After all necessary modifications are made, click on Save to store the modifications. If you have changed the modulation type, the VPort will automatically restart. If the Reset network at next boot option is checked, perform the software installation again. Otherwise, the VPort will boot up automatically using the new configuration settings.
COM 1 & COM 2
There are 2 COM ports, COM 1 and COM 2, in VPort 2140 Video Server for connecting the external devices, such as Motorized PTZ controller, Modem, or Multiplexer.
|
|
| Speed |
COM 1 | DB9 Male | Terminal block for Data+, Data- | Max. 115. 2 Kbps |
COM 2 | DB9 Male | N/A | Max. 115. 2 Kbps |